Technical data

WimTec INSIDE - 230 V:
Supply voltage:
Power consumption:
Magnetic valve:
Main flush:
Stadium mode:
Stagnation flush:
Dry-out protection:
Blockage protection:
Flow pressure:
Flow rate:
Urinals:
20
Urinal control WimTec INSIDE
230 V 50 Hz
approx. 3 VA
1/2" 24 V LP
adjustable from 1 - 15 s
can be enabled,
starting with 3 uses within 1.5 min,
the flush is activated once a minute
can be enabled,
flushing interval: after 3 h to 48 h of non-usage,
flushing duration: as main flush
serves to restore the odour trap
can be enabled,
flushing aborted if blocked
0.05 - 0.6 MPa (0.5 - 6 bar)
approx. 0.3 to approx. 0.7 l/s at 0.3 MPa
(3 bar) can be reduced acc. to EN 12541
For urinals with a level urinal outlet at the back.
Urinals with avertical siphon e.g. Laufen Taro Nova
only with siphon adaptor (Art.No. 231 311)