INTENDED USE

Measuring and displaying electric parameters in the range of overvoltage CAT II for up to max. 600 V
against ground potential, pursuant to EN 61010-1 and all lower categories.
Measurement of direct and alternating voltage up to 600 V
Measurement of direct and alternating current up to 10 A
Frequency measurement up to 60 MHz
Capacity measurement up to 6 mF
Measuring impedance values of up to 60 MΩ
Continuity test (<70 Ω acoustic)
Diode test
Temperature measurement from –40 to +1000 ºC
The measurement functions are selected using the rotary control. The measuring range is selected
automatically for all measuring functions (except for diode and continuity tests). Manual setting is
possible at any time.
The VC610BT shows actual effective measured values (True RMS) in the direct and alternating
voltage and current measuring area.
Polarity is automatically indicated with the prefix (-) in case of negative measured values.
The two current measuring inputs are secured against overload with ceramic high-performance
fuses.
The voltage in the current measuring circuit must not exceed 600 V in CAT II.
The multimeter is operated with six 1.5 V batteries type C or 230 V/AC, 50 Hz. Automatic switching off
saves power if the device is not used for approx. 10 minutes. (The function is activated only when the
multimeter is powered by batteries). When the interface is active, this function is switched off.
Measuring in damp rooms or under unfavourable ambient conditions is not permitted. Unfavourable
ambient conditions are: Moisture or high air humidity, dust and flammable gases, fumes or solvents,
thunderstorms or thunderstorm conditions like strong electrostatic fields, etc.
Only use measuring leads or accessories which are adjusted to the specifications of the multimeter
when measuring.
Unauthorised conversion and/or modification of the device are inadmissible because of safety and
approval reasons (CE). Any usage other than described above is not permitted and can damage the
product and lead to associated risks such as short-circuit, fire, electric shock, etc. Please read the
operating instructions thoroughly and keep them for further reference.
observe all safety instructions and information within this operating manual.