kind of absolute value (like kiln temperature etc.)
VAL S: Programme value in the range of 127 to 128. Typically used for any kind of
relative values (like offset temperature for zones)
EVENT: EVENT value, ie. holds ON or OFF. When requiring multiple events defining
them one after the other saves programme memory
01: designator
Used to give each programme table column an individual name (consisting of up to
3 alphanumeric letters)
following parameters apply on selection TIME only:
02: lower time lim
Limits the value range entered as a time. Note that the values smaller than minus 2
enable the programme link feature ( 3 = allow linking to programme number 1, 4 =
allow linking to programme number 2 etc.)
03: upper time lim
Upper limit when adjusting the time. The 1000 steps beyoind this limit stand for
setting the gradient as centigrade kelvin per period
following parameters apply on selection VAL L only:
12: value unit
Specifies the unit of the programme table value
13: lower val. lim
Lower limit of the programme table value. Used to limit the programm values
within the operation range of the kiln
14: upper val. lim
Upper limit of the programme table value. Used to limit the programm values
within the operation range of the kiln
34
(alphanumerical characters)
(value range 101 to 0)
(value range 1 to 599)
(options °C, °F, °K, dg, mV, mA,
O2, CO, %, ev, mb, m³, m³h, kh,
kwh, Pa, AT, lda)
(value range 99 to 1999)
(value range 99 to 1999)
following parameters apply on selection VAL S only:
32: value unit
Specifies the unit of the programme table value
33: lower val. lim
Lower limit of the programme table value. Used to limit the programm values
within the operation range of the kiln
34: upper val. lim
Upper limit of the programme table value. Used to limit the programm values
within the operation range of the kiln
following parameters apply on selection EVENT only:
42: EVENT number
This unique identifier assigns the EVENT in the programme table for the digital
output
.
Table 6: process flow
Following settings specify how any unusual conditions during programme run (such
as a broken temperature sensor, slow heating, control loop errors etc.) are
handled. Also the criterias to enter the next segment during programme run can be
adjusted to your application
.
00: time in ramps
If the temperature of the pilot input (IN00) is higher than the start temperature of
the ramp the time of the ramp can be either kept or reduced accordingly
KEEP: Segment time is kept, setpoint begins as programmed
UPDAT: Segment time is reduced accordingly. Example: Segment 0 at 0°C, segment
(options °C, °F, °K, dg, mV, mA,
O2, CO, %, ev, mb, m³, m³h, kh,
kwh, Pa, AT, lda)
(value range 128 to 127)
(value range 128 to 127)
(value range 0 to 3)
(options KEEP, UPDAT)
operating instructions bentrup TC20xx V1.9