Additional Process Values (TC2088 only)
In more complex installations it might by required to monitor additional process values (indi-
vidual input signals on averaged inputs, mV of an input etc.). In complex configuration mode
(see next chapter) you can define a list of parameters to be shown during programm run.
After programe is started press both arrow keys simultaneously to enter additional process
value display. Now using the arrow keys you can navigate through the list of process values
defined in the configuration such as input values (IN), analog input signals (AI), control loop
state (LP), analog output values (AO), digital output values (DO) etc.
For example fig A. shows the current status of the digital outputs DO (output DO0 and DO4
(A)
active).
Fig B. shows the current mV input signal of AI2 (4.209 mV). The first digit on the lower dis-
play reads the input number (example AI 2)
After 15 seconds the display reverts back to normal reading.
(B)
22
operating instructions bentrup TC20xx V1.9