S 12 (TC2044): first ramp temperature
Final temperature of the first ramp (default 580°C). Always set in °C
S 12 (TC2066): default setpoint display
On particular customized version only: show program setpoint as default reading.
S 12 (TC2088e): segments per program
Number of segments per program. Less number of segments results in more
programs (total 300 seg). Example: 10 segments per program >30 programs.
S 12 (TC2010): operating mode
Determines TC2010 operating mode refer to the manual for details: 0=signal
converter, reading and limiter / 1=setpoint controller / 2=setpoint controller with
adjustable heat up ramp / 3=setpoint controller with adjustable heat up ramp and
dwell / 4=watchdog controller / 5=slave contoller for master/slave operation
following parameters are available ONLY if digital inputs are fitted:
S 13: DI0 operation mode
0 = program start from the beginning / 1 = program start at current segment / 2 =
program stop / 3 = ON program start from the beginning, OFF program stop / 4 =
ON program start at current segment, OFF program stop / 5 = ON program HOLD,
OFF program continue
S 14: DI1 operation mode
options refer to S 13
following parameters are available ONLY if digital outputs DO2/DO3 are fitted:
S 15: DO2 operation mode
0=heating (value contains cyclus time) / 1=safety output / 2=EVENT (value
contains event no.) / 3=ON during firing / 4=ON during the firing except segment
0 / 5=ON when firing completed / 6=cooling (value contains cyclus time)/ 7=ON if
temperature > value / 8=ON if temperature < value
S 16: DO2 value
optional value for operation mode DO2
operating instructions bentrup TC20xx V1.9
(value range 20 to 1000)
(value range OFF, ON)
(value range 5 to 99)
(value range 0 to 5)
(value range OFF, 0 to 5)
(value range 10000 to 10000)
(value range OFF, 0 to 8)
(value range 10000 to 10000)
S 17: DO3 operation mode
options refer to S 15
S 18: DO3 value
optional value for operation mode DO3
following parameters are available ONLY if logic outputs DO4/DO5 are fitted:
S 19: DO4 operation mode
options refer to S 15
S 20: DO4 value
optional value for operation mode DO4
S 21: DO5 operation mode
options refer to S 15
S 22: DO5 value
optional value for operation mode DO5
following parameters are available ONLY if analog outputs are fitted:
S 23: AO0 signal type
Signal type of analog output AO0
S 24: AO0 operation mode
0=heating / 1=cooling / 2=setpoint (range 0°C to temperature set by parameter S
02) / 3=process value (range 0°C to S 02)
S 25: AO1 signal type
Signal type of analog output AO1
S 26: AO1 operation mode
options refer to S 20
(value range OFF, 0 to 8)
(value range 10000 to 10000)
(value range OFF, 0 to 8)
(value range 10000 to 10000)
(value range OFF, 0 to 8)
(value range 10000 to 10000)
(value range OFF, 0 10V, 0 20mA,
4 20mA)
(value range OFF, 0 to 8)
(value range OFF, 0 10V, 0 20mA,
4 20mA)
(value range OFF, 0 to 8)
27