Instructions for installation and use
● Post-drying programme
Once combi-mode has inished, the post-drying programme starts automati-
cally to prevent mould or rot from forming in the sauna room. This involves
heating the sauna room to 80 °C with the fan running for 30 minutes.
● Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches the sauna
heater off at a temperature of approx. 139 °C.
3.4.
Sauna operating modes
The sauna control unit Pro B3 provides two operating modes, sauna mode and
combi mode.
Sauna mode
Dry heat is provided in sauna mode. The temperature in the room is high (80 to 100 °C)
The humidity level of maximum 10% is low.
Combi mode
The evaporator operates along with the sauna heater in combi mode. The tem-
perature in the sauna room is lower (approx. 40 to 65 °C) than in sauna mode, with
the relative humidity being considerably higher, spanning 35% to approximately
70%. The maximum humidity level which can be set depends on the temperature
of the sauna. The higher the sauna temperature, the lower the maximum humid-
ity level which can be set.
3.5.
Sensor operating modes
The sauna control unit can be operated with one or two sensors. A temperature
sensor (bench sensor, F2) or a humidity sensor (FTS2) can be used as the
second sensor.