Herunterladen Inhalt Inhalt Diese Seite drucken

Settings; Reducing The Temperature; Cleaning, Care And Maintenance; Troubleshooting - AEG MTH 350 Bedienungs Und Installationsanleitung Handbuch

Hydraulisch gesteuerter, offener klein-durchlauferhitzer mit blankdrahtsystem
Vorschau ausblenden Andere Handbücher für MTH 350:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. Settings

The appliance heating system switches on automatically
as soon as you open the DHW valve at the tap or activate
the sensor of a sensor tap. The water is heated. The water
temperature can be adjusted at the tap:
For the start volume, see chapter "Specification / Data
table / On".
Increasing the temperature
» Reduce the flow rate at the tap.

Reducing the temperature

» Open the tap further or add more cold water.
Following an interruption of the water supply
See chapter "Commissioning / Recommissioning".
5. Cleaning, care and
maintenance
» Never use abrasive or corrosive cleaning agents. A
damp cloth is sufficient for cleaning the appliance.
Material losses
!
Scale build-up at the tap outlets can put the appli-
ance under pressure and may cause irreparable
damage.
» Check the taps/valves regularly. Limescale deposits
at the spouts can be removed using commercially
available descaling agents.
Operation - for users and contractors
» Have the electrical safety of the appliance regularly
checked by an electrician.
» Regularly descale or replace the special aerator (see
chapter "Appliance description / Accessories").

6. Troubleshooting

Problem
Cause
The appliance will not
No power to the ap-
start despite the DHW
pliance.
valve being fully open.
The aerator in the tap
is scaled up or dirty.
The water supply has
been interrupted.
If you cannot remedy the fault, notify your qualified con-
tractor. To facilitate and speed up your enquiry, please
provide the serial number from the type plate (000000 /
0000-00000).
MTH . . .
000000
Model:
E-Nr:
0000-00000
F-Nr:
Remedy
Check the fuses/
MCBs in your fuse
box.
Clean and/or descale
the aerator or replace
the special aerator.
Vent the appliance
and the cold water
inlet line (see chapter
"Settings").
29

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mth 440Mth 570

Inhaltsverzeichnis