Fault
The temperature in
the cool fresh"
compartment is too
cold or too warm.

Customer service

Your local customer service can be found in the
telephone directory or in the customer service index.
Please provide customer service with the appliance
product number (E Nr.) and production number (FD).
This information can be found on the product label.
To prevent unnecessary call outs, please assist customer
service by quoting the product and production numbers.
This will save you additional costs.
Possible cause
The fixed setting has been set too
high or too low (e. g. if there is frost
in the cool fresh" compartment).
Remedial action
The temperature in the cool fresh" compartment
can be changed to be 2 steps warmer and/or colder.
If the bargraph is set to 4, the cool fresh"
compartment has a temperature of almost 0 °C.
The numbers on the temperature display lamps
do not correspond with the temperatures in the
cool fresh" compartment.
Setting 2 coldest setting
Setting 8 warmest setting
Press button 2 for 3 seconds until a beep sounds,
temperature display lamps 4 flicker.
Change the setting with button 3.
After one minute, the set temperature is stored.