7.4.1
µA DC current range (BENNING MM 6-1)
The input resistance is approx. 3 kΩ.
Overload protection: 1000 V
Measuring range
600.0 µA
7.5 AC current ranges (BENNING MM 6-2)
Overload protection:
-
11 A (1000 V AC/ DC) fuse, 20 kA, rapid on 10 A input
Max. measuring time:
-
3 minutes at > 5 A (pause > 20 minutes)
-
30 secondes at > 10 A (pause > 10 minutes)
Measuring
OL indication
range
6.000 A
10.00 A
*
6 A measuring range from ≥ 20 mA, 10 A measuring range from ≥ 100 mA
7.5.1
μA AC current range (BENNING MM 6-1)
The input resistance is approx. 3 kΩ.
Overload protection: 1000 V
Measuring
OL indication
range
600.0 µA
*
Measuring range from ≥ 1 µA
7.6 Resistance ranges
Overload protection: 1000 V
Measuring range OL indication
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
*
Measured values > 10 MΩ might cause changing values on the display
(max. ± 50 digits).

7.7 Diode testing

Overload protection: 1000 V
Max. no-load voltage: 1.8 V
Measuring range OL indication
1.500 V

7.8 Continuity testing

Overload protection: 1000 V
The built-in buzzer sounds in the case of a resistance R less than 20 Ω up to 200
Ω. For a resistance R higher than 200 Ω, the buzzer does not emit an acoustic
signal. Additionally, in case of continuity, the red LED N on the top side of the
device lights.
Measuring range OL indication
600.0 Ω
7.9 Capacity ranges
Conditions: capacitors discharged and connected in accordance with the polar-
ity stated.
Overload protection: 1000 V
Measuring range OL indication
1.000 µF
10.00 µF
02/ 2016
AC/DC
OL indication
660.0 µA
Resolution
6.600 A
0.001 A
20.00 A
0.01 A
AC/DC
Resolution
660.0 µA
0.1 µA
AC/ DC
Resolution
660.0 Ω
6.600 kΩ
0.001 kΩ
66.00 kΩ
660.0 kΩ
6.000 MΩ
0.001 MΩ
40.00 MΩ
AC/ DC
Resolution
1.550 V
AC/ DC
Resolution
660.0 Ω
AC/ DC
Resolution
1.100 µF
0.001 µF
11.00 µF
BENNING MM 6-1/ 6-2
Resolution
0.1 µA
in frequency range 45 Hz - 500 Hz (sine)
± (1.5 % of reading + 5 digits)*
± (1.5 % of reading + 5 digits)*
in frequency range 45 Hz - 500 Hz (sine)
± (1.5 % of reading + 5 digits)*
0.1 Ω
0.01 kΩ
0.1 kΩ
0.01 MΩ
0.001 V
0.1 Ω
0.01 µF
Measurement accuracy
± (1.0 % of reading + 5 digits)
Measurement accuracy
Measurement accuracy
Measurement accuracy
± (0.9 % of reading + 8 digits)
± (0.9 % of reading + 5 digits)
± (0.9 % of reading + 5 digits)
± (0.9 % of reading + 5 digits)
± (0.9 % of reading + 5 digits)
± (1.5 % of reading + 8 digits)*
Measurement accuracy
± (0.9 % of reading + 5 digits)
Measurement accuracy
± (0.9 % of reading + 8 digits)
Measurement accuracy
± (1.9 % of reading + 8 digits)
± (1.9 % of reading + 5 digits)