600
14.2 Securing the appliance to
the cabinet
1.
Open the appliance door.
2.
Fasten the appliance to the cabinet.
Put the four distance holders (A) into
the holes in the frame and then
tighten the four screws (B) supplied
with the appliance.

15. ENVIRONMENT CONCERNS

Recycle the materials with the
symbol
applicable containers to recycle it.
Help protect the environment and
human health and to recycle waste
of electrical and electronic
min. 550
20
min. 560
A
. Put the packaging in

14.3 Electrical installation

WARNING!
Only a qualified person must do
the electrical installation.
The manufacturer is not responsi-
ble if you do not follow the safety
precautions from the chapter
"Safety Information".
This appliance is supplied with a main
plug and a main cable.
14.4 Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the
total power (on the rating plate) and to
the table:
Total power
B
maximum 1380
W
maximum 2300
W
maximum 3680
W
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
appliances. Do not dispose
appliances marked with the symbol
with the household waste. Return the
product to your local recycling
facility or contact your municipal
office.
ENGLISH
33
Section of the ca-
ble
3 x 0.75 mm²
3 x 1 mm²
3 x 1.5 mm²