• Do not apply force to avoid damage of sealing surfaces.
Check sealing surfaces inside the spray gun [8-2] after disassembly,
clean them, if required. Should the sealing surfaces be damaged,
please contact your SATA dealer. Align new air distribution ring by
means of the 12 o'clock marking [8-3], (pin into drilling) and press in
with even force. Adjust material flow according to chapter 7.2 after in-
stallation.
9.3. Replacing the paint needle seal
[7-3], [9-1], [7-4], [7-5] and [7-6]
When paint material leaks from the self-tensioning paint needle packing,
it needs to be replaced. After disassembly, check if paint needle is dam-
aged or replace the nozzle set, if required. Adjust material flow according
to chapter 7.2 after installation.
9.4. Replacing the air piston, air piston spring and
air micrometer
• Disconnect spray gun from the compressed air circuit!
When air leaks from the air cap or the air micrometer without the trigger
being pulled, they need to be replaced. After disassembly, grease the air
micrometer [10-2] and spring [10-3] with SATA high performance grease
(Art. No. 48173), insert them together with the air piston and thighten
the locking screw [10-1]. Adjust material flow according to chapter 7.2
after installation.
• Check if locking screw [1-9] has been firmly tightened! Air micrometer
[1-8] could shoot out from the spray gun uncontrolled!