Gas regulations

The gas type and pressure that have been preset
in the factory are indicated on the rating plate
close to the gas connection on the back side of
the cooker. If the cooking appliance is set up for a
different type of gas than that available, its injec-
tors, sometime its by-pass as well must be
replaced, the minimum flow regulated. In order to
replace the injectors in the cooking hob, it is nec-
essary to carry out the following operations:
• Prior to making the necessary adjustments, dis-
connect the hob from the mains.
• remove the pan supports;
• remove the burners and burner caps (Fig. A);
• take out the injector (Fig. B) and replace it with
one suitable for the new type of gas (see
"GENERAL INJECTORS TABLE");
• replace the gas label (on the rear of the appli-
ance) with the new one provided with the injec-
tors kit;
• refit all parts by following the disassembly
instructions in reverse order and taking care to
position the burner cap correctly on the burner.
• In the event that the appliance has to be con-
verted to LPG 30/50 mbar the by-pass of the
taps must be substituted. We recommend to
contact the technical service for this operation.