(5) H/MAX Switch
This switch has two modes, one is data hold the other is maximum
hold. Sliding the function switch to power on, this switch will work
in data hold mode. Pressing the H/MAX switch then slide the
function switch from power off to power on, this switch will work in
maximum hold mode.
Data Hold mode
This mode is used to hold measured value for all functions, push
this switch then HOLD annunciator is displayed. Conversions are
made but the display is not updated.
Maximum Hold mode
This mode is used to hold the maximum measured value for all
functions except continuity mode. Press this switch the "MAX"
annunciator turns on then enters the maximum hold mode. Press
this switch again to restart recording. Press this switch more than 2
seconds to exit the maximum hold mode.
(6) Zero Switch
This switch is used to zero the reading on display. It work in DC and
AC current function only. In zero mode, the reading maybe exceed ±
4000 counts.
(7) Ω/AC/DC Selection switch
Push this switch alternately to measure AC voltage or DC voltage in
the V ~ function or to measure AC current or DC current in the A ~
function. or to measure resistor or continuity in Ω/function. Auto power
disable mode - press this switch until slide the function switch power
on for 1 second it will cause the auto power off function disable.
(8) Trigger
Press the lever to open the transformer jaws. When the pressure on
the lever is released, the jaws will close again.
(9) Hand Guard
Designed to protect user for safety.
(10) Transformer Jaws
Designed to pick up the AC/DC current flowing through the conductor.
-23-
2. Technische Daten
2.1. Allgemeine Daten
Anzeige
Polarität
1
Überlaufanzeige
Batteriezustandsanzeige
Messfolge
Positionsfehler
Messprinzip
max. Zangenöffnung
max. Leiterdurchmesser
Temperaturkoeffizient
Spannungsversorgung
Batterielebensdauer
Abmessungen
Gewicht
mitgel. Zubehör
3 3/4-stellig LCD-Anzeige; max. Anzeige
3999
automatische
Umschaltung;
negativem Messwert
Anzeige des Minussymbols (-) links vom
Messwert
"OL" wird in der LCD-Anzeige dargestellt
Batteriesymbol erscheint in der Anzeige
2 x pro Sekunde
± 1 % v. Messwert
Hall-Effekt-Sensor (AC und DC)
25 mm
22 mm
0.15 x (garantierte Genauigkeit)/°C bei
< 18° C oder > 28° C
2 x 1.5 V Batterien (AAA)
ca. 60 Stunden (Alkali-Batterien)
66 (B) x 192 (L) x 27 (H) mm
205 Gramm (inkl. Batterien)
Prüfleitungen,
Batterie,
Anleitung
-4-
bei
Tasche,