NexPro
2.17.2

TABLE USER PARAMETERS (Utt)

Parameter
Default
Ut1
55.0
Ut2
55.0
2.17.3

Table Manufacturer Parameters (CoS) / Menu Configuration (CFn)

Parameter
Default Limits
H01
55
15-60
H05
8
-20 -30
H07
65
60-70
H08
365
1-365
H09
3
1-5
H10
15
15-30
H11
6
6-24
H15
0
-5 -5
H16
0
-5 -5
H18
000
0-255
H19
0
0-1
H20
90
0-255
H21
100
0-255
H22
30
0-255
H23
1
0-1
H26
3
0.0 - 15.0
H27
55
30-70
H28
3
0.0 - 15.0
H29
1
0-1
H30
1
0-1
H32
1
0-1
H33
0
0-1
H34
1
0.5 -2
H35
20
15 - 25
H36
10
5 - 10
H50
1
1-2
H60
0
0-1
H70
0
0-1
Limits
Unit
Description
15-H01
°C
Water Setpoint in AUTOMATIC mode
15-H27
°C
Water Setpoint in MANUAL mode
Unit
Description
°C
Max Value Boiler Setpoint with heat pump
°C
Setpoint outdoor air temperature to activate the electrical heater
°C
Thermal shock Setpoint
days
Interval of antibacterial treatment
Num(1)
Number of repetitions for each treatment cycle
min
Duration of treatment cycle (time of staying at thermal shock temperature)
hours
Time between two cycles
°C
Offset probe S1 (input AI1)
°C
Offset probe S2 (input AI2)
Num(3)
Manufacturer Password (to access parameter 2nd level)
Num(1)
Internal parameter
10 SEC.
Minimum time between switching off and switching on - Time OFF-ON
[expressed in ten-second intervals]
10 SEC.
Minimum time between two successive starts -Time ON-ON [expressed
in ten-second intervals]
sec
Probe S1 permanency time at the boiler set point value
Num(1)
Enable Auto start function [1=enabled]
°C
Differential activation Heat Pump (Automatic mode)
°C
Value Max Boiler Water Setpoint (Manual mode)
°C
Differential activation electrical heater (Manual mode)
Number
Enable air probe S2 (0=disabled;1=enabled)
Number
Enable digital input ID2 [0=disabled - 1=enabled]
Num(1)
Enable antibacterial treatment
Num(1)
Enable dynamic setpoint
Num
Slope of the compensation
°C
Outdoor air temperature above which the compensation starts
°C
Excursion of outdoor air temperature on which the setpoint works
Num(1)
Selection of integrative source [1=Electrical heater; 2 = Boiler]
Num(1)
Enable electrical heater ON OFF [0=disabled; 1 = enabled]
Num(1)
Enable remote ON OFF [0=disabled; 1 = enabled]
26