between the actual temperature and humidity can be acti-
vated or deactivated. If the automatic switch is deactivated
("OFF"), only the actual temperature will be displayed.
• Press the auto/manu button (
• Select the menu item „t-H" with the handwheel and con-
firm with the boost button ( ).
• Set the option „On" to activate automatic switching or set
the option „OFF" to deactivate automatic switching with
the handwheel.
• Confirm with the boost button ( ).
Switch between the actual temperature and
humidity is only possible if the actual temperature
has been selected under "S-A".
15.8 Teach-out devices (dEL)
Devices that are taught-in to the room thermostat can be
taught-out with the function "dEL". All taught-in devices are
deleted simultaneously.
• Press the auto/manu button (
• Use the handwheel to select the menu item "dEL" and
confirm this with the boost button.
• The display will show "no". Select "YES" with the hand-
wheel. Confirm with the boost button ( ) to delete all
taught-in devices.
The menu item "dEL" will only be displayed as long
as the devices are not taught-in to the central
control unit.
) longer than 3 seconds.
) longer than 3 seconds.
Configuration menu