Herunterladen Inhalt Inhalt Diese Seite drucken

Motor Connection - Lenze EVS9321 Montageanleitung

Vorschau ausblenden Andere Handbücher für EVS9321:
Inhaltsverzeichnis

Werbung

5.5.5

Motor connection

)
Note!
ƒ
ƒ
Shield sheet installation
(
Stop!
Do not use lugs as strain relief.
T1
T2
Fig. 5−10
EDKVS9332X DE/EN/FR 4.0
Standard devices in the power range 15 ... 30 kW
Fusing the motor cable is not required.
The drive controller features 2 connections for motor temperature
monitoring:
– Terminals T1, T2 for connecting a PTC thermistor or thermal contact
(NC contact).
– Pins X8/5 and X8/8 of the incremental encoder input (X8) for connecting a
KTY thermal sensor.
PE
U
V
3.4 Nm
a
a
30 lb-in
0
Installation of shield sheet for drive controllers 15 ... 30 kW
0
Fasten the shield sheet with two self−tapping screws Æ 4 × 14 mm (a)
l
Electrical installation
Motor connection
W
5
9300vec131
163

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis