Herunterladen Inhalt Inhalt Diese Seite drucken

Overcurrent Operation - Lenze EVS9321 Montageanleitung

Vorschau ausblenden Andere Handbücher für EVS9321:
Inhaltsverzeichnis

Werbung

3.3.3

Overcurrent operation

3.3.3.1
Operation at 400 V
Basis of the data
AC mains connection
DC−mains connection
(alternatively)
Output voltage
With mains choke
Without mains choke
9300
Mains current
With
mains choke
Type
I
[A]
r
EVS9321−xx
1.5
EVS9322−xx
2.5
EVS9323−xx
3.9
EVS9324−xx
7.0
Bold print = Lenze setting
1)
Mains currents at 8 kHz switching frequency
2)
Switching frequency of the inverter
3)
Power which can additionally be drawn from the DC bus at operation with power−adapted motor
9300
Rated current
Type
I
[A]
r8
EVS9321−xx
1.5
EVS9322−xx
2.5
EVS9323−xx
3.9
EVS9324−xx
7.0
1)
Switching frequency of the inverter
2)
The currents apply to a periodic load change cycle with max. 10 seconds overcurrent duration and 50 seconds base
load duration at max. 44 % of the rated current
3)
70 % of the rated current
EDKVS9332X DE/EN/FR 4.0
Voltage
[V
3/PE AC 320 V − 0 % ... 440 V + 0 %
rate
]
d
[U
]
DC 450 V − 0 % ... 620 V + 0 %
DC
3 ~ 0 approx. 94 % V
3 ~ 0 ... U
1)
Typical motor power
Without
ASM
mains choke
(4−pole)
I
[A]
P
[kW]
r
r
2.1
0.37
3.5
0.75
5.5
1.5
˘
3.0
1)
8 kHz
Continuous
Maximum
Standstill
2)
thermal
current
current
3)
current
I
[A]
I
[A]
r8
M8
1.05
3.0
1.75
5.0
2.73
7.8
4.9
14.0
l
Technical data
Overcurrent operation
rated
N
Output power
2)
8 kHz
U, V, W
P
[hp]
S
[kVA]
r
r8
0.5
1.0
1.0
1.7
2.0
2.7
4.0
4.8
Output currents
Rated current
Continuous
thermal
current
I
[A]
I
[A]
I
08
r16
3.0
1.1
5.0
1.8
7.8
2.9
14.0
5.2
Rated data
Frequency
45 Hz − 0 % ... 65 Hz + 0 %
˘
˘
˘
Power loss
3)
+U
, −U
G
G
P
[kW]
P
[W]
DC
V
2.0
100
0.75
110
2.2
140
0.75
200
1)
16 kHz
Maximum
Standstill
2)
current
current
3)
[A]
I
[A]
I
r16
M16
016
0.77
2.2
2.2
1.26
3.6
3.6
2.03
5.8
5.8
3.64
10.4
10.4
3
[A]
127

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis