Motor Connection - Lenze 8200 motec Montageanleitung

Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3
Wall mounting

Motor connection

{
Danger!
After the connection of a PTC thermistor or thermal contact
l
all control terminals only have a basic insulation (single
insulating distance).
Protection against contact in the event of a defective
l
insulating distance can only be ensured by external measures
(e.g. double insulation).
X2
T1 T2
PE W V U
0.5...0.6 Nm
4.4...5.3 lb-in
3.4 Nm
30 lb-in
8200mot006
Use low−capacity motor cables! (Core/core £ 75 pF/m, core/shield £ 150 pF/m)
0
Use short motor cables if possible!
Cable cross−sections U, V, W, PE:
E82MV551_4B, E82MV751_4B
E82MV222_4B, E82MV152_4B
1
Route a separate cable (shielded) to X2/T1 and X2/T2 for the motor temperature monitoring.
Route the control and mains cables separately from the motor cable!
88
X2
T1 T2
T1
J >
X2
Fig. 15
1a
1a
® 1 mm
® 1.5 mm
EDK82MV222 DE/EN/FR 8.0
PE
W V U
T2
PE
1a
B
A
2
(AWG 18), shielded
2
(AWG 16), shielded
0.5...0.6 Nm
4.4...5.3 lb-in
5.5 mm
2
2.5 mm
AWG 12
6mm
3.4 Nm
30 lb-in
L