Programmable Transmitter for Position Feedback
Residual ripple in
output current:
Response time:
Programming connector
Interface:
Accuracy data
Reference value:
Basic accuracy:
Reproducibility:
Reference conditions
Ambient temperature
Power supply
Output burden
Additional errors (cumulative)
Output characteristics
simple "V" characteristic
"V" characteristic with offset
any characteristic
Camille Bauer
< 0.3% p.p.
< 5 ms
Serial interface
Measuring span
Error limits at reference conditions
≤ ± 0.5%
< 0.2%
23 °C ± 2 K
18 V DC
0 Ω
Data Sheet SR 719 Le – 02.08
Possible adjustability
of the built-in
KINAX 2W2
Infl uence effects (maxima)
(included in basic error)
Dependence on external
resistance Δ R
max.
ext
Power supply infl uence
Additional error (maxima)
Temperature infl uence
(– 25...+ 75 °C)
Bearing play infl uence
Defi nitions
Angle max. = MW
Angle min. = 0°
MS = (angle max.) – (angle min.)
Angle max. = ± fi nal angle
Angle min. = > 0°
MS = (angle max.) – (angle min.)
KINAX SR 719
> 50...350°
Linear characteristic
The measuring range is set to
approx. 0...90º.
± 0.1%
± 0.1%
± 0.2% / 10 K
± 0.1%
Additional error
0.18°
f = (
x 100)
MW
0.25°
f = (
x 100)
MS
0.25°
f = (
x 100)
MS