7.0

Technical Data

(at 23° C ± 5° C, max. 75 % rel. humidity). Temperature coefficient (<18°C or >28°C):
0.15 (Specified Accuracy) /°C
Display:
Range Selection:
Auto-Power-Off:
Overload display:
Measuring rate:
Clamp opening:
Overvoltage Categorie:
Pollution degree:
Height above MSL.:
Battery display:
Power supply:
Current Consumption:
Operation temperature:
Storage temperature:
Dimension:
Weight:
Voltage AC TRMS
Crest Faktor <4, Input Impedance 10MΩ, max. Peak Voltage 850 Vss
Range
5 V...600 V
20 V...600 V
Overvoltageprotection: 800V AC
Current AC TRMS (mA and A)
Crest Faktor <4, max. Peak Voltage 850 mAss (mA Range) or
70 Ass (A Range)
Range
0,50...60,00 mA
60,00...99,99 mA
100...600,0 mA
0,050...3,000 A
3,000...9,99 A
10,00...30,00 A
30,00...50,00 A 0
4digit, LCD incl. functions and symbols
automatic
approx. 30 min.
OL
2 measurements/sec. (LCD)
ca. 30 mm (1.2 inch)
CAT II, 600 V / CAT III, 300 V
2
up to 2000 m
at low battery
Batterie 2 x 1,5 V IEC LR6 (alkaline)
approx. 10 mA
-10° C ... 50° C at less than 85% rel. H.
-20° C ... 60° C at less than 75% rel. H.
210 x 62 x 35,6 mm
approx. 200 g
Resolution
0,1 V
0,1 V
Resolution
0,01 mA
0,01 mA
0,1 mA
0,001 A
0,001 A
0,01 A
0,01 A
Accuracy
± 0,5 % ± 5 D (50/60Hz)
± 1,5 % ± 5 D (45-1kHz)
Accuracy (50/60Hz)
± 0,5 % rdg. +5 D
± 0,5 % rdg. +50 D
± 0,5 % rdg. +5 D
± 0,5 % rdg. +5 D
± 0,5 % rdg. +50 D
± 0,5 % rdg. +5 D
± 1,0 % rdg. +5 D
14