6.0 Technical Data

LED voltage range
LED resolution
Tolerance
LCD voltage range*
LCD resolution*
Tolerance*
Voltage detection
Acoustic signal
Polarity detection
Range detection
Response time
Frequency range
Automatic load (RCD)
Internal basic load
Peak current
Operation time
Recovery time
Auto Power On
Single-pole Phase Test
Voltage range
Frequency range
Resistance Measurement
Resistance range
Tolerance
Test current
Overvoltage protection
Continuity Test
Resistance range
Accuracy
Test current
Overvoltage protection
Rotary Field Indication
Voltage range (LEDs)
Frequency range
Measurement principle
Power supply
Power consumption
Temperature range
Humidity
Height above sea level
Overvoltage class
Degree of contamination
Type of protection
Safety complying to
Weight
Dimensions (HxWxD)
* only UNITEST beta and gamma / ** only UNITEST 2000 gamma
Technical Data
12...690V AC/DC
±12, 24, 50, 120, 230, 400, 690V
complying to DIN VDE 0682, Part 401
12V...690V AC/DC
1V
±(3% rdg. +3digits)
automatic
(AC voltage) yes
full range
automatic
<0.1s LED / <2s LCD
0...400Hz
yes
approx. 2.1 W at 690V
Is <0.2A / Is(5s) < 3.5mA
ED (DT) = 30s
10min
<12 V AC/DC
100...690V AC
50...400Hz
0...1999Ω/1Ω
±(3% v.M. + 3 Digit)
<300µA
690V AC/DC
0...400kΩ
RN +50%
5µA
690V AC/DC
100...690V
50...60Hz
double-pole and contact electrode
2 x 1.5 V Micro IEC LR03
max. 30mA / approx. 250mW
-10°C...55°C
max. 85% relative humidity
up to 2000m
CAT III / 690V
2
IP65
DIN EN 61243-3, DIN VDE 0682 Part
401 (first DIN VDE 0680 Part 5, EN
61010, IEC 61010)
180g (incl. batteries)