10 Troubleshooting

Problem
Torch necks gets hot • Contact tip/tip adapter not tightened
Wire burned solid in
the contact tip
Irregular wire feed
Arc between gas
nozzle and work-
piece
Erratic arc
Pore formation
Tab. 8
Troubleshooting
11 Dismounting
NOTE
• Some problems are listed below, with descriptions of possible causes and
solutions. If the measures described below are not successful, please
consult your dealer or the manufacturer.
• Please also consult the operating instructions for the welding components,
such as power supply, air pressure line.
Cause
• Power connections loose on the torch
side and toward the work-piece
• Wrong parameters set
• Contact tip worn out
• Contact tip and wire diameter not
matched
• Wrong contact pressure set on the wire
feed unit
• Spatter bridge between contact tip and
gas nozzle
• Contact tip not matched to the wire
diameter or contact tip diameter
enlarged
• Wrong welding parameters set
• Strong spattering in the gas nozzle
• Insufficient or missing gas cover
• Air currents blowing shielding gas
away
Dismounting may only be carried out by specialized personnel. Please make
sure that the shutdown procedures are strictly observed, before the dismounting
work begins. Ensure this also for the components integrated into the welding
system.
10 Troubleshooting
Solution
• Check and tighten
• Check and tighten
• Check or correct setting
• Replace
• Replace contact tip
• Correct as specified by
manufacturer
• Clean and spray gas nozzle
interior
• Check contact tip
• Correct welding parameters
• Clean gas nozzle
• Check gas cylinder contents and
pressure setting
• Shield welding area with partitions
EN - 15