9 Maintenance and cleaning
9.1 Torch neck
9.2 Wire guide
EN - 14
NOTE
• The maintenance intervals given are recommended values and refer to
single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
• Always wear your personal protective clothing when performing
maintenance and cleaning work.
 Fig. 4 auf Seite EN-10
1 Remove gas nozzle (12) .
2 Remove welding spatter and spray gas nozzle using the ABICOR BINZEL
anti-spatter agent.
3 Check wearing parts for visible damage and replace them, if required.
4 If neck liner is present, replace it when worn or soiled.
5 Clean separating point and O-rings with silicone-free sealing grease.
 Fig. 4 auf Seite EN-10
1 Unscrew the cable assembly (7) on the machine side and bring it into a
straight position.
2 Pull out wire guide (8) .
WARNING

Risk of injury

Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable
protective clothing, in particular safety goggles.
3 Clean wire feed hose from both sides with compressed air.
4 Slide wire guide (8) into wire feed unit and secure it with the spigot nut (5) .
®