Please Read
Immediately

1.1 Important Information

ATTENTION!
The device cover cannot be used for carrying (the cover cannot withstand
larger forces!)
ATTENTION!
When installing the on-site pipework, ensure the pipes do not get
contaminated (flush pipes before connecting HW HP)!
ATTENTION!
Only operate HW HP when filled with water!
ATTENTION!
Disconnect the power supply before opening the HW HP; observe
possible coasting of ventilator.
ATTENTION!
Ensure water does not come into contact with the operator controls.
Unplug mains plug/disconnect the power supply before beginning any
cleaning work.
E-2
1.2 Regulations / Safety
Information
ATTENTION!
Read these installation and operating instructions before start-up!
The hot-water heat pump (HW HP) is exclusively used to
heat water for domestic use and drinking water within the
specified operating temperature limits! Heating fluids other
than domestic water is not permitted. Observe the technical
regulations for domestic water installation (DIN 1988).
Exhaust air should not fall below +15 °C (evaporator may
freeze). Sinking exhaust air temperatures reduce economi-
cal heat pump operation.
It is not permitted to
operate the pump with solvent-laden or explosive exhaust
-
air
- use exhaust air containing fat, dust or sticky
aerosols
- to connect extractor hoods to the
ventilation system
Installation of the device is not permitted
- outdoors
- in rooms which are exposed to frost
- in wet rooms (e.g. bathrooms)
- in rooms with air which is potentially explosive
because of gases, vapours or dust
Operation of the device is not permitted
- with an empty cylinder
- during building construction
The construction and design of the HW HP complies with all
relevant EG directives (see also CE declaration of conform-
ity).
The technician must ensure that the refrigerant is flushed
adequately to allow maintenance and repair work on refrig-
erant circuit components without risk. Refrigerant must be
properly used and disposed of; it must not be released into
the environment! (The refrigerant R134a is CFC-free, non-
inflammable and not ozone depleting.)
When working on the HW HP, always disconnect the power
supply.
When connecting the HW HP to the power supply, the rele-
vant VDE, EN and IEC standards are to be fulfilled. Also ob-
serve the technical connection requirements of the electrical
utility companies.
ATTENTION!
Work on the hot-water heat pump is to be performed by qualified
personnel only!
Observe accident prevention regulations!