Herunterladen Inhalt Inhalt Diese Seite drucken

Adjusting The Water Flow; Functions Of The Leds In The Water Heater - clage MBX 3 Lumino Gebrauchs- Und Montageanleitung

Kleindurchlauferhitzer
Vorschau ausblenden Andere Handbücher für MBX 3 Lumino:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12. Adjusting the water flow

May only be carried out by a specialist.
Remove the cover (see Fig. 11), undo the hood screw underneath and remove the hood.
Decreasing the flow rate:
Turn the adjusting screw clockwise to decrease the flow rate, thus making a higher outlet tem-
perature possible.
Increasing the flow rate:
Turn the adjusting screw counter-clockwise to increase the flow rate, thus reducing the pos-
sible outlet temperature.
13
Direction

13. Functions of the LEDs in the water heater

Green LED...
...flashes regularly
...lights on
Red LED...
...lights on
...flash code:
long-short-long-short-long
long-short-short-short
long-short-long
Tem pe ra ture
Flow
in crease
+
+
Standby mode
Appliance is heating water
Maximum power reached; the desired outlet temperature cannot be
reached.
Defective heating spiral
Faulty temperature sensor
Air bubble in system
29