8. Installation and water connections

158
A
The following regulations must be observed:
• EN 806
• Installation must comply with all statutory regulations, as well as those of the local
electricity and water supply companies.
• Only intact and appropriate tools must be used
• If this unit is exposed to mains water pressure, the water container may start
leaking and cause damage.
• Make sure that no accessories are left in the packing.
• Install the water heater vertically. Water connection on top and in a frost-free room.
Use the screws and dowels included or similar mounting material (depending on
the wall condition) in horizontal position with a distance of 140 mm.
• Never expose appliance to frost.
• Do not close outlet pipe and the swivel spout of the fittings. Only use CLAGE-jet con-
trol for pressureless water storage heaters.
The spout also functions as a vent. Only special open-outlet (non-pressure) taps are
allowed for installation with this appliance. Follow the manual of the tap as the
flow must be regulated to 5 l / min. The flow rate must not be exceeded even when the
water pressure is high on a temporary basis.
A correct flow rate results in:
• reduced noises
• a large volume of mixed water.
The coloured markings on fitting pipes and unit must match:
blue = cold water inlet
red = hot water outlet
140
If you confuse the connections, the hot water heater will not function or will be
damaged.
Compression nut must not be on toe-out A , forced tightening will destroy water-
connections!