Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy Quattro 12/5000/200 Anleitung Seite 12

2x30 – 230/240v
Vorschau ausblenden Andere Handbücher für Quattro 12/5000/200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Special indications
Set with limited input current
charger
mains on
on
bulk
off
absorption
charger
only
float
Set to supply additional current
charger
mains on
on
bulk
off
absorption
charger
float
only
8
inverter
inverter on
The AC voltage on AC1-in-1 or
AC-in-2 is switched through. The
overload
AC-input current is equal to the
load current. The charger is down-
low battery
controlled to 0A.
temperature
inverter
inverter on
The AC voltage on AC-in-1 or
AC-in-2 is switched through, but the
overload
load demands more current than
the mains can supply. The inverter
low battery
is now switched on to supply
additional current.
temperature