17 Troubleshooting

17.1 Troubleshooting
Condition
LEDs on Battery
Blower does not start
1 LED flashes
when switched on
green
1 LED glows red.
3 LEDs flash red.
3 LEDs glow red
4 LEDs flash red
Blower cuts out during
3 LEDs glow red
operation
Blower runtime is too
short
40
Cause
Battery has low charge
Battery too hot or too cold.
Malfunction in blower.
Blower too hot.
Malfunction in battery.
No electrical contact
between blower and battery.
Blower or battery damp.
Blower too hot.
There is a electrical
malfunction.
Battery not fully charged
Remedy
Charge the battery, @ 6.1.
Remove the battery, @ 8.2.
Allow battery to cool down / warm up.
Remove the battery, @ 8.2.
Clean contacts in battery compartment, @ 15.1.
Fit the battery, @ 8.1.
Switch on the blower, @ 9.1.
If 3 LEDs continue to flash red: Contact your
STIHL servicing dealer.
Remove the battery, @ 8.2.
Allow blower to cool down.
Remove the battery and refit it, @ 8.
Switch on the blower, @ 9.1.
If 4 LEDs continue to flash red: Contact your
STIHL servicing dealer.
Remove the battery, @ 8.2.
Clean contacts in battery compartment, @ 15.1.
Fit the battery, @ 8.1.
Allow blower or battery to dry.
Remove the battery, @ 8.2.
Allow blower to cool down.
Remove the battery and refit it, @ 8.
Switch on the blower, @ 9.1.
Fully charge the battery, @ 6.1.