17 Troubleshooting

17.1 Troubleshooting Blower or Charging Cable

Condition
LEDs on blower
Blower does not start
1 LED flashes
when switched on
green
3 LEDs glow red
3 LEDs flash red. There is a electrical
Blower cuts out
3 LEDs glow red
during operation
Blower runtime is too
short
Blower is not being
3 LEDs glow red
charged.
38
Cause
Blower has low charge.
Blower too hot.
malfunction.
Blower is damp.
Blower too hot.
There is a electrical
malfunction.
The blower is not fully
charged.
Normal blower life has
been exceeded.
Blower too hot.
Malfunction in blower or
charging cable.
Remedy
► Recharge the blower.
► Remove the activation key.
► Allow blower to cool down.
► Remove the activation key.
► Contact your STIHL servicing dealer.
► Allow the blower to dry.
► Remove the activation key.
► Allow blower to cool down.
► Switch off the blower, wait 5 seconds and then
switch on again.
► Fully charge the blower.
► Replace the blower.
► Remove the activation key.
► Allow blower to cool down.
► Remove the activation key.
► Contact your STIHL servicing dealer.