before switching accessories or when performing
repairs.
- Never aim the air flow at yourself or others.
• Hoses flapping about can result in serious injuries.
Therefore always inspect hoses and their fasteners
for damage and a secure fit.
• Direct cold air away from hands.
• If using universal swivel couplings (coupling discs)
always use locking pins and use whipcheck hose sa-
fety cables for protection in the event the connection
between the hose and the machine or in between
hoses fail.
• Be sure not to exceed the maximum pressure speci-
fied on the machine.
• Never carry pneumatic tools by the hose.
Commissioning
Note: The device is fully functional as delivered.
Inserting the bit or drill
• Loosen the keyed chuck (1) using the wrench (9)
(see Fig. A).
• Now insert the bit extension (10) as far as possible
into the keyed chuck 1 and attach the bit (11) (see
Fig. A).
• To secure the bit extension (10) , tighten the keyed
chuck 1 using the wrench (9) (see Fig. B). Ensu-
re the bit extension (10) and the bit (11) are seated
securely. Insert the drill as in these steps (see Fig.
A and C).
Connecting
Note: only use connection hoses with a minimum in-
side diameter of 9 mm.
• First wrap a piece of Teflon tape (not included)
around the outer threads of the plug nipple (8) and
the lubricator (13).
• Now screw the plug nipple (8) into the thread of the
lubricator (13) (see Figure D).
• You must use an open-end spanner to tighten this
connection with moderate force.
• Now turn the combination of lubricator (13) and plug
nipple (8) into the connection thread (5) of the im-
pact driver (see Fig. D).
• Also retighten this connection with an open-end
spanner.
• Now press the air hose onto the plug nipple (8)
using a little force, until the hose locks in. (see Figu-
re E)
• ATTENTION! Be sure the air hose is firmly con-
nected. A loose hose whipping about out of control
presents a major hazard. Also ensure the two screw
connections between lubricator (13) , coupling and
machine are securely seated.
Adjusting the compressed air
Note: this device is designed for an operating pressu-
re of up to 6.8 bar and a compressor with the minimum
air flow specified in the technical specifications. When
setting the air pressure, remember the pressure drops
by approx. 0.6 bar with a hose length of 10 m and an
inner diameter of 9 mm.
• Only use filtered, lubricated and regulated com-
pressed air.
Initial use
• Activate the On / Off switch (3) to start using the
device.
• Release the On/ Off switch (3) to switch the device
off.
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
Changing rotation
• ATTENTION! The device must come to a complete
standstill before changing the direction of rotation.
• ATTENTION! A machine rotating in an unexpected
direction can be dangerous. Always pay attention
and use care. Note: The power drill is designed for
clockwise/ counter-clockwise rotation. Use the for-
ward/reverse switch (4) to change the direction of
rotation of the power drill.
• Set the forward/reverse switch (4) to position F to
switch to clockwise rotation.
• Set the forward/reverse switch (4) to position R to
switch to counter-clockwise mode.

After initial use

Once the task has been finished the device must be
disconnect from the compressed air supply (5) .
• Briefly activate the On / Off switch (3) on the device
to bleed any residual compressed air.
• Now pull back the safety on the connection coupling
of your compressed air hose.
• Now remove the hose from the plug nipple (8) .
WARNING! Careful when putting the device down.
Always put down the device so it does not rest on the
trigger. This could potentially result in inadvertent acti-
vation of the tool, which in turn could result in hazards.

Maintenance

ATTENTION! All maintenance must be performed by
trained individuals. Follow the specified maintenance
instructions to ensure a long life and proper operation
of this quality product.
• Disconnect equipment from the compressed air
source when performing maintenance and care.
• Check the condition of wear and tear items and
accessories with each maintenance. Note: Daily
cleaning and regular lubrication are an absolute ne-
cessity for smooth operation.
• Only use special tool oil with a high viscosity (thin
fluid). Oil for compressed air tools or SAE10-20 mo-
tor oil are suitable. ATTENTION! Do not use other
(especially high viscosity) lubricants. Malfunctions or
permanent damage may otherwise occur.
The following lubricating options are available:
a) via the lubricator (13)
• Fill the lubricator included (13) with a bit of oil by
first unscrewing the inlet screw from the lubricator.
• Now install the lubricator (13) in the compressed air
supply as described in chapter „Establishing con-
nections".
b) via oil-mist generator
• If a complete maintenance unit with oil-mist gene-
rator is installed on your compressor the lubricator
(13) does not necessarily need to be mounted.
• To use the oil-mist generator plug the plug nipple (8)
directly into the equipment and connect with your air
hose.
c) by hand
Alternatively you can also manually lubricate your
equipment (not recommended).
To do so, remove the screw plug on the oil filler port.
Apply 3–5 drops of oil to the compressed air connec-
tion before using the compressed air tool (4) .
If the air tool has not been used for several days 5–10
drops of oil must be added to the air connection (5) .