6. TECHNICAL DATA

Model
Generator
IP class:
Continuous power S1 (RPR):
Maximum power S2, 2 min.:
Rated voltage:
Rated current:
Frequency:
Drive engine design
Quality class
Performance class
Displacement
Max. power:
Fuel:
Tank capacity:
Consumption at 3/4 load
Weight:
Sound pressure level LpA:
L
guaranteed sound power level/K
WA
uncertainty
Max altitude
Max working temperature
Type of spark plug
Type of fuel
Operating mode S1 (continuous operation)
The machine can be continuously operated with the quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the quoted power output. Afterwards the ma-
chine must be stopped for a while to prevent it from overheating.

7. Before putting the machine into operation

7.1 Electrical safety:

Electric supply cables and connected equipment must be in perfect condition.
The generator is to be operated only with equipment whose voltage specifications conform
with the generator's output voltage.
Never connect the generator to the power supply (socket-outlet).
Keep the cable length to the consumer as short
as possible.

7.2 Environmental protection

Dispose of soiled maintenance material and operating materials at the appropriate collection
point.
Recycle packaging material, metal and plastics.
44
GB
SG950
Synchronous
IP23M
650VA / 650W
720VA / 720W
230V~
3,0A ~
50 Hz
2-stroke, air-cooled
Class B
G1
63cm³
1,2 kW / 2,0 PS
mix 1:40
4,0 l
ca. 0,8 l/h
17 kg
71 dB(A)
94 dB(A) / 2 dB(A)
1000 m
40°C
LD F6TC
Unleaded Gasoline, or 90 Octane (E10)