f) Possible Errors of PWM

No phone number displayed in the status
Activate caller ID transmission in the mobile phone
SMS arrives but PWM is not switched
No PWM authorisation:
Enter wrong phone number
Caller ID transmission deactivated
Called from another mobile phone or configuration not transmitted.
Spaces included or capitalisation not observed.

g) Possible Errors of IN1 and IN2

Signal is not recognised, status does not indicate IN1,IN2=L,H
Wrong voltage: The signal must be a direct voltage of at least 3 V and most 12 V/DC
Duration too short: Signal must be present for about 3 seconds before it is recognised.
Signal incorrectly connected: Connect minus to mark "-" and plus to the right
SMS is only sent after the voltage is removed again
"Message when input high" active in the software.
Signal is recognised, status also indicates IN1,IN2=L,H, but does not send SMS
Signal was applied right after switching on: The module will only check for changes
at the inputs after approx. 1 minute. Therefore disconnect the signal, wait for a
moment and connect it again.
Not enough credit on the prepaid card