• Now you can trace the status in the control software under "Communication".
• The display must change to the voltage value applied to the input behind "ADC".
• Once the voltage exceeds 1 V (value above "1000"), the message "SMS sent" must appear;
the entered message text must be sent to the mobile phone by SMS.
Matching application examples for use of the ADC input are available online at
www.conrad.com at the respective product.
Important!
Generally, the GSM module only indicates changes that persist for at least 3 seconds
or undercut/exceed the threshold value. If you have sent a new configuration to the
GSM module, the GSM module will restart automatically. The GSM module takes 1
minute after restart before it can perform any changes to the sensors or commands.
This waiting time must be strictly observed!