Herunterladen Inhalt Inhalt Diese Seite drucken

PR Elecronics 9116 Handbuch Seite 138

Vorschau ausblenden Andere Handbücher für 9116:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LERBAKKEN 10, 8410 ROENDE DENMARK
Hazardous area
Zone 0,1,2, 20, 21, 22
0/4-20 mA
Current source
Module 9116B 1/2
Terminal 51-52
Ui
30 V
Ii
120 mA
Pi
900 mW
Ci
3 nF
Li
2 μH
Module 9116B 1/2
Term. 52-51, 51-52
Uo
16.6 V
Io
0.2 mA
Po
0.8 mW
Revision date:
2010-02-12
+
-
Group
Co
IIC
0.4 μF
100 mH
IIB
2.3 μF
100 mH 100mH/Ω
IIA
9.5 μF
100 mH 200mH/Ω
Version Revision
V5 R0
Non Hazardous area
or Zone 2
-20 ºC ≤Ta ≤ +60ºC
4501
54
34
53
33
52
32
51
31
44
14
43
13
42
12
41
11
9116
Power Rail
4501
54
34
53
33
52
32
51
31
44
14
43
13
42
12
41
11
9116
Power Rail
Lo
Lo/Ro
25mH/Ω
Prepared by:
9116QA01
Status relay, terminal (33,34)
Non hazardous area installation
Voltage max:
125 VAC / 110 VDC
Power max:
62.5 VA / 32 W
Current max:
0.5 A AC / 0.3 ADC
Zone 2 installation:
Voltage max:
32 VAC/ 32 VDC
Power max:
16 VA / 32 W
Current max:
0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Non hazardous area installation
Voltage max:
250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max:
2 A AC / 2 ADC
Zone 2 installation
Voltage max:
32 V AC / 30 VDC
Power max:
64 VA / 60 W
Current max:
2 A AC / 2 ADC
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
253 V max. 400 Hz
m:
PB
Page:
4/4

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

9116v101-in1031

Inhaltsverzeichnis