Menu 4 Further door settings
Menu
Entry
Selection
item
43
Floor adjustment
0
off (default setting)
1
on
44
Hold-open time in seconds
0
0 s (default setting)
1 - 30
1 s - 30 s (in increments of 1 s)
31 - 60 35 s - 180 s (in increments of 5 s)
61 - 99 190 s - 22.5 min (in increments of 30 s)
45
Status relay X5
0
Door close signal (default setting)
1
Door open signal
2
Status of door for traffic light control A800
3
2-minute garage light
4
5-minute garage light
5
On / off with hand-held transmitter (menu
item 62)
6
ELTACO wipe pulse
46
Status relay X6
0
Door close signal
1
Door open signal (default setting)
2
Status of door for traffic light control A800
3
Locking
4-14
Warning light closing (0 - 10 s warning time)
15-25
Warning light opening and closing (0 s - 10 s)
48
Force detection settings
0
Force detection inactive
1-99
Force detection cycle active, permissible over-
current 101-199 % of the current measured dur-
ing the force learning cycle.
The following values can be used as
a guide:
Settings for spring-balanced doors (approx.
200 kg)
20 – very high sensitivity
25 – high sensitivity (approx. 20 kg)
40 – medium sensitivity
60 – low sensitivity
Settings for heavy spring balanced doors
(approx. 450 kg)
8 – very high sensitivity
9 – high sensitivity (approx. 20 kg)
13 – medium sensitivity
21 – low sensitivity
Settings for heavy springless doors (ap-
prox. 320 kg)
2 – very high sensitivity
5 – high sensitivity (approx. 20 kg)
6 – medium sensitivity
7 – low sensitivity
Settings for heavy springless doors (ap-
prox. 380 kg)
2 – very high sensitivity
6 – high sensitivity (approx. 20 kg)
7 – medium sensitivity
8 – low sensitivity
Default value: 20
Menu 4 Further door settings
Menu
Entry
Selection
item
49
Motor duty cycle
0
Without limitation (default setting)
1
Geared motor 5.24 (25 min / 35 %)
2
Geared motor 5.24 WS (25 min / 30 %)
3
Geared motor 9.15, 9.20, 9.24 (25 min / 60 %)
4
Geared motor 9.24 WS (25 min / 20 %)
5
Geared motor 6.65 DU (10 min / 35 %)
6
Geared motor 14.15 (25 min / 60 %)
- -
Exit menu
Menu 5 Various settings
Menu
Entry
Selection
item
50
Key switch function (J7)
0
Pulse input OPEN/CLOSE (default setting)
1
Inhibit control panel
2
Inhibit external control elements
3
Inhibit control panel and external control elements
4
Activate control elements for 10 seconds
5
Switch-over to dead man mode for closing
6
Switch-over to 1/2 opening (winter mode)
7
Pulse input OPEN-STOP-CLOSE
8
Pulse input 1/2 OPEN-STOP-CLOSE
9
Automatic closing AR
10
Pulse input for smoke and heat extraction sys-
tem (setting in menu item 55)
11
Pulse input for smoke and heat extraction sys-
tem, inverted (setting in menu item 55)
12
Mutual locking of door
51
Function of external control devices
0
off (default setting)
1
Dead man open / dead man close
2
Pulse open / dead man close
3
Pulse open / pulse close
4
Pulse 1/2 door opening / pulse close
5
AR operation, automatic closing
6
AR operation, 1/2 door opening
7
Open-close operation
8
Open / close pulse as NO contact
52
001-256 Entry of control address
53
Plug-in module
0
off (default setting)
1, 2, 3, 4 DC module
5
RSE system with OSE
6
RSE system with 8k2
55
Door setting for smoke and heat extraction sys-
tem position
58
RSE selection of wicket door contact
Press for 5 s: delete pairing of RSE-system
0
ENS-8200
1
ENS-S 68xx (default setting)
2
NC contact
- -
Exit menu