Programming control elements
1
3
4
1 LED display
2 LED spot (confirmation of
the programming entry)
Rating plate
The rating plate is located at the side on the control housing. Ob-
serve the power supply specifications.
1
7
Made in Germany
6
5
4
1 Control type
2 Manufacturer and address
3 Supply voltage
4 Amperage
Technical data
Control unit
Rating plate no.
Height x width x depth
Cable feed-throughs
Supply voltage
Control voltage
External power supply
Max. motor power
Safety according to
EN 13849-1:
Protection type
Operating temperature
Manufacturer
22 - EN
2
5
3 Up navigation button
4 Down navigation button
5 Programming button (Prog
button)
2
3
5 Max. motor power
6 Protection type
7 Rating plate no.
T100 R-FU 1.5 kW
15335050850
520 mm x 215 mm x 120 mm
Assembled vertically
6 x M20
2 x M16
2 x M20 V cutout
1~ 230 V
24 V DC
max. 700 mA
max. 1.5 kW
Input STOP A: Cat. 2 / PL = C
Input STOP B: Cat. 2 / PL = C
Input STOP C: Cat. 2 / PL = C
IP 54 / CARA plug = IP44
+50 °C
-20 °C
Novoferm tormatic GmbH
Eisenhüttenweg 6
D-44145 Dortmund
www.tormatic.de
4
Installation
Hazardous voltage
DANGER
The product works with low voltage
(230/400 V AC). Before starting with the installa-
tion,observe the following:
•
•
Follow the instructions as well as the illustrations in the
"Connection diagrams" chapter.
1.
Tools required
For the assembly of the control, you require the following tools:
•
wooden folding rule or tape measure
•
cross-tip screwdriver Phillips; size 2
•
drilling machine
•
drill 6 mm
•
Torx screwdriver, size T20
•
slotted screwdriver for electricians
•
spirit level
•
marking pencil
2.
Opening the control cover
Hazardous voltage
DANGER
The product runs on high voltage Before opening
the frequency converter cover, observe the fol-
lowing:
•
•
•
•
Open the top and bottom housing cover by loosening the screws
on either the left or right on the cover.
3.
Assembly of the control
Assemble the control as specified on the drilling drawing.
Selection of the place of installation
NOTICE
When selecting the place of installation, observe
the preconditions in compliance with the tech-
nical data.
4.
Terminal designation
J1
Start / pulse input (OPEN / STOP / CLOSE
J2
Photoelectric safety barrier 2- or 4-wire
J3
Safety edge OSE / 8K2 / DW / light grid
J4
Emergency stop, slack rope, locking
J5
No function
J6
Anti crash detector
J7
Key switch / pull switch
J8
Timer inputs
J9
Digital limit switch
J10
Connection of extended controls
J11
Connection of radio receiver
J12
Antenna
J13
Membrane keypad
J14
Plug-in module (DC, RSE)
T100 R-FU 1,5kW
Have all work on electrical connections car-
ried out by a skilled electrician.
The power connection must be executed in
compliance with the mains voltage avail-
able.
Disconnect all poles of the mains voltage.
Allow residual voltage to dissipate for
1 minute.
Secure against unauthorised switch-on.
Operation without the frequency converter
cover is not permitted.