Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Installing The Power Unit; Installing The Main Switch; Installing The Cabin Light And The Light Switch - Sentiotec Wc4-B-11 Installations- Und Gebrauchsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 40
Instructions for installation and use

4. Installation

During installation observe the technical data; see Page 37:
ATTENTION!
Interference can impair signal transmission
● Route all sensor cables separately from other mains cables and control cables.
● Protect cables with only one layer of insulation by using a conduit (double
insulation).
● The sensors may only be connected using the sensor cables supplied
with the unit, which are heat-resistant up to 150 °C.
● The heater sensor cables may NOT be longer than 10 m.
● Outside the cabin, the sensor cables can be extended using cables
that are not temperature-resistant.

4.1. Installing the power unit

See Fig. 2 on Page 14.
ATTENTION!
Damage to the unit
The sauna controller is resistant to splashing water, but direct contact with water
could still damage it.
● Install the sauna controller in a dry place where the maximum humidity will
not exceed 95%.
● When installed in the sauna cabin, the cable bushings must not point upwards!
To install the power unit
1. Take off the cover of the power unit.
2. You can fasten the power unit to the supporting surface at the 4 corners of
the chassis (see arrows Fig. 4 on page 17)

4.2. Installing the main switch

Follow the operating instructions for the switch.

4.3. Installing the cabin light and the light switch

Follow the operating instructions for the switch.
, carry out the following steps:
1
p. 13/38
EN
Inhaltsverzeichnis
loading

Inhaltsverzeichnis