Remarks:
• A particular input (IN1 or IN2) can be simultaneously assigned to both outputs – it means that it
is possible to control channel 1 or channel 2 by means of this input.
• In case the switch on/switch off mode is selected, then only one input can be chosen to realise
the switch on function, and the second input will realise the switch off function – in this mode, it
is possible to control independently only one channel or two channels simultaneously.
• In case of push-buttons, inputs react only to short impulses (rising edge). An exception includes
the monostable mode with an input switched on as long as the push-button connected to a
receiver's input is pressed.
• In case of bistable switches, inputs react only to the rising and falling edge. It means, each
switch position change triggers a particular mode.
• The structure of outputs is designed to a long term trigger, which is very important during switch
application.
OUTPUT MODE CONFIGURATION
AFTER POWER SUPPLY SWITCH ON
In case of ROP-22 receiver, it is possible to configure its input operation mode after power supply
has been switched on. As a default setting, the receiver's input is switched off.
Possible output modes:
• switched off,
• switched on,
• previous mode - after power supply has
been switched on, the input mode is the
same as before power supply failure. Time
mode is an exception – if power supply is
switched off during time measurement, then
after power supply is switched on again –
the input remains in the switched off mode.
After power supply is switched on, the output
operation mode is adjusted in the receiver
configuration tab (of the particular channel).
Input configuration
list for Channel 1 of
ROP-22