'ZONE TIME' PROGRAMMING
• Each new push-button assigned to ROP-22 in time mode operates with the so-called zone
time. The default zone time is adjusted to 10 seconds. A user can change the zone time value
in the range from 1 second to 18 hours. After time zone has been changed, the push-buttons
assigned to a receiver in time mode should automatically operate with the new value of the zone
time. The exception includes push-buttons with assigned individual times.
• Zone time value can be directly changed by means of a receiver and its PROG. push-button or
a mobile application, if the receiver is paired with the EXTA LIFE controller.
DIRECT PROGRAMMING OF ZONE TIME
(by means of the PROG. push-button)
Zone time change for output 1 (OUT-1)
1. Press the PROG. push-button shortly (1sec.) in a receiver –STATUS LED switches on blue.
2. Wait for about 5 seconds till the STATUS LED switches on red.
3. Wait again for about 5 seconds till the STATUS LED switches off.
4. After the LED is switched off, in < 5 sec. press shortly the PROG. push-button.
5. The STATUS LED starts flashing blue – it means time is measured.
6. After the time we want to assign as zone time for output -1, press shortly the PROG. push-
button again.
7. The STATUS LED flashes orange to signal time has been programmed correctly.
Zone time change for output 2 (OUT-2)
1. Press the PROG. push-button shortly (1sec.) in a receiver –STATUS LED switches on blue.
2. Wait for about 5 seconds till the STATUS LED switches on red.
3. Wait again for about 5 seconds till the STATUS LED switches off.
4. And again wait for about 5 seconds till the STATUS LED flashes blue.
5. After the LED is switched off, in < 5 sec. press shortly the PROG. push-button.
6. The STATUS LED starts flashing red – it means time is measured.
7. After the time we want to assign as zone time for output -2, press shortly the PROG. push-
button again.
8. The STATUS LED flashes orange to signal time has been programmed correctly.
REMOTE PROGRAMMING OF TIME ZONE
Remote zone time change for ROP-22 is also possible by means of a mobile application. To do
it, pair the given receiver with the EXTA LIFE system controller. After pairing, the ROP-22 device
is visible in the system as 2 channels (Channel 1 and Channel 2). Next, to adjust zone time for a
particular channel choose the "Configure" option from the receiver's menu. Then, from the con-
figuration screen set basic parameters for the particular receiver (channel).
In case of zone time, it is required to adjust the "Zone Time" parameter in the range from 1 sec. to
18 hrs. in the following form: hours: minutes: seconds: (xxh: xxm: xxs).