CONNECTION
FUNCTIONALITY
1. The ROP-22 receiver can be simultaneously controlled by:
• EXTA LIFE system transmitters (switch on / switch off, bistable, monostable, time),
• EXTA LIFE mobile application, after pairing with a controller (switch on / switch off and time
modes)
• IN1, IN2 external inputs (operating mode depends on a switch type – see Functionality of
inputs).
2. Current receiver's output mode is shown in the mobile application.
3. It is possible to assign a larger number of push-buttons of EXTA LIFE transmitters to one re-
ceiver (channel) – maximum 96 pairs (e.g. 24 transmitters in the switch on/switch off mode).
4. Transmitters' push-buttons can be assigned to a receiver "locally" by means of a mobile applica-
tion.
5. Few transmitters can cooperate with one transmitter – it is recommended that a transmitter
is assigned to each receiver in the switch on / switch off mode.
6. A receiver can be paired only with one EXTA LIFE controller. After pairing the receiver is not
visible for other controllers.
7. Push-buttons added to a receiver's memory can be selectively deleted.
8. There is a possibility to delete simultaneously all push-buttons added to a receiver's memory
(reset to default settings).
9. Basic ROP-22 parameters are configured by means of a mobile application.
10. Parameters are independently configured for OUT1 and OUT2 outputs.
11. A remote software update of a receiver is also possible due to a mobile application (the EXTA
LIFE controller must be connected to the Internet).
DEFAULT SETTINGS
Parameter
OUT1, OUT2 modes after power
supply has been applied
input types: IN1, IN2
IN1, IN2 input operation mode
default time for output OUT1, OUT2* • 10 s
*refers to push-buttons assigned to a receiver in time mode
Default settings
• switched off
• cooperation with monostable
(push-buttons) switches
• bistable
Configuration
possibilities
• yes – mobile application
• yes – mobile application
• yes – mobile application
• yes – mobile application
• PROG push-button