MOUNTING
• The ROP-22 receiver is designed to be mounted in a junction box. Its dimensions enable flush
(Ø60 minimum) and surface mounting. In case of a flush junction box, a deepened box is recom-
mended, as it makes mounting easy with a large number of wiring and a big cross-section of
connection wires.
• The device is designed for single-phase installation and must be installed in accordance with
standards valid in a particular country. The device should be connected according to the details
included in this manual instruction. Installation, connection and control should be carried out by
a qualified electrician staff, who act in accordance with the service manual and the device func-
tions. For safety reasons, do not mount the device without casing or with a damaged one, as an
electric shock may occur.
• After power supply has been applied, the receiver will carry out service activities for about 5
seconds (it is signalled by a green STATUS LED, it will flash at an interval of 1 second). During
this time the receiver's control is not possible.
CAUTION: Before installation make sure the connection cables are not under voltage.
INSTALLATION:
1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector com-
bined to the proper circuit.
2. Check if there is no voltage on the connection cables by means of a special measuring equip-
ment.
3. Connect the device cables with the terminals in accordance with the installing diagram.
4. Install ROP-22 in a junction box.
5. Switch on the power supply from the mains.
MOUNTING REMARKS
1. Do not mount receivers in a close proximity to each other (if there is a possibility, keep a distance
of minimum 15 cm between receivers). Particularly, avoid installation of one receiver over the
another.
2. The maximum output load must be obeyed:
• incandescent and halogen lamps: 750 W / channel,
• fluorescent CFL lamps: 250 W / channel,
• dimmable LEDs: 60 W / channel.
3. During mounting, make sure the receiver is not exposed to direct water and operation in an in-
creased humidity environment. The mounting ambient temperature range should be within the
range from -10 to + 55 °C.
4. The ROP-22 receiver is designed to be mounted indoor. In case the receiver is mounted outdoor,
it must be placed in an additional hermetic casing.
5. Wired control switches can be connected to the IN1 and IN2 inputs of ROP-22 receiver. By de-
fault, the inputs are adapted to cooperate with monostable push-buttons in a bistable mode. It
means that each subsequent impulse given to the IN1 or IN2 input causes the output mode is
changed to an opposite mode.
6. After a receiver has been installed, it is important to check, if it operates correctly. In case of
control by means of the EXTA LIFE system transmitters, they must be first programmed with a re-
ceiver (see Programming transmitters). In case of cooperation with a controller, a correct pairing
of a receiver with a controller is required (see Register of receivers in the EXTA LIFE system).
CAUTION: Input functionality (switch type, operation mode) can be changed by means of the
EXTA LIFE mobile application. It is necessary to install a controller in the system and pair it
with ROP-22 receiver – see Input functionality.