INPUT FUNCTIONALITY
• The IN1 and IN2 inputs of ROP-22 receiver are fully configured, but only by means of the EXTA
LIFE mobile application. The configuration refers to choosing the type of switch that is con-
nected to a IN1/IN2 inputs, the operation mode of a particular input and the channel switching
on time, in case time mode has been selected. The application allows for the so-called input
'mapping', it means a switch connected to the IN1 input can control channel 2, and a switch
connected to the IN2 input can control channel 1.
• Default settings – refer to both inputs (IN1 and IN2):
- Switch type: monostable (1 push-button)
- Operation mode: bistable.
- IN1 input controls channel 1 (OUT1).
- IN2 input controls channel 2 (OUT2).
Input configuration change:
1. Activate the application and enter the Device screen.
2. To configure channel 1 (OUT1) operation by means of wired inputs of ROP-22, select the 'Con-
figure' option from this channel menu. Carry out analogical steps to configure channel 2 (OUT2)
operation - select the 'Configure' option for this channel.
3. Expand the configuration screen and, first, define the 'Input type' field. There are two types of
switches to choose:
• monostable (push-button) switch,
• bistable (push-button) switch,
4. Next, define the 'Input mode'. The operation modes depend on the previously selected 'Input
type'.
Monostable switch modes
monostable
switch on / switch off
5. Next, with reference to the selected input mode, choose the input number that should control
the particular channel (it refers to the following modes: bistable, time, monostable, switch on/
switch off). In case of switch on/switch off mode, it is important to select the input that should
realise the switch on function.
6. In case of time mode selection, it is required to additionally define the switching on time pa-
rameter of an input by means of the wired input. Time is defined in the range from 1 sec. to 18
hrs. in the following form: hours: minutes: seconds.
CAUTION: The switching on time is assigned to an input. There is not a possibility that
a receiver's output is switched on with time t1 by means of IN1 input and with time t2 by
means of IN2 input.
7. Press the 'Save' button to save all settings – the settings will be saved in the receiver.
bistable
time
switch on
switch off
Bistable switch modes
bistable
time
-
switch on / switch off
switch on
switch off