Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Migatronic AUTOMIG2 i Betriebsanleitung

Vorschau ausblenden Andere Handbücher für AUTOMIG2 i:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15

Technical data

POWER SOURCE
Mains voltage ±15% (50-60Hz), V
Minimum short-circuit power Ssc, MVA
1
Fuse, A
Mains current, effective, A
Mains current, max., A
Power, (100%), kVA
Power, max., kVA
Power, open circuit, W
Efficiency
Power faktor
Current range, A
Duty cycle
100%
20°C, A
Duty cycle
40%
20°C, A
Duty cycle
max.
20°C, A/%/V
Duty cycle
100%
40°C, A/V
Duty cycle
60%
40°C, A/V
Duty cycle
35%
40°C, A/V
Duty cycle
max.
40°C, A/%/V
Open circuit voltage, V
Sphere of application
2
Protection class
3
Standards
Dimensions (HxWxL), mm
Dimensions DUO (HxWxL), mm
Weight, kg
Weight DUO, kg
Data for Boost-version are stated at 1x230V mains supply
Data in parenthesis are stated at 3x400V mains supply
** = Power save function. The machine will enter the power save
function 7.5 minutes after finalising the welding operation
1)
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the
stated data in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution
network operator if necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in
the abovementioned table.
2)
S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
3)
Equipment marked IP23/IP23S is designed for indoor and outdoor applications.
AUTOMIG
AUTOMIG
2
2
183i/183i DUO
233i/233i DUO
3x400
3x400
0.47
0.69
10
10
4.4
6.8
7.5
11
3.1
4.7
5.2
7.6
15/10**
15/10**
0.86
0.86
0.93
0.93
15-180
15-230
160
220
180
230/50/25.5
115/19.8
165/22.3
125/20.3
175/22.8
200/24.0
180/25/23.0
230/25/25.5
45
45
S/CE
S/CE
IP23S
IP23S
EN/IEC 60974-1. EN/IEC60974-5. EN/IEC60974-10
660x380x790
660x380x790
960x600x850
960x600x850
26.2
26.5
41.2
41.5
AUTOMIG
AUTOMIG
Boost
2
2
273i/273i DUO
273i/273i DUO
3x400
3x230-400. 1x230-400
10
16
7.6
10.5
13.2
42.0
5.3
2.4(3.0)
9.1
9.7(9.5)
20
30
0.88
0.84
0.93
0.99
15-270
15-270
230
150 (180)
245
180 (200)
175/22.8
107 (135)/19.4(20.8)
205/24.3
130 (170)/27.5(22.5)
270/30/27.5
270/18(25)/27.5
52
55
S/CE
S/CE
IP23
IP23
550x250x640
550x250x640/960x570x870 (DUO)
960x570x870
26
28 / 57 (DUO)
55
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: AUTOMIG
2
i
As of week 02 2013
conforms to directives:
2006/95/EC
2004/108/EC
2011/65/EU
European standards:
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Issued in Fjerritslev on 7 January 2013.
Anders Hjarnø Jørgensen
CEO
13