7.2 Connecting the hydraulic system in standard configuration
The lift is shipped with the hydraulic system in the following conditions (fig.1):
-
Pipes (4-5) are connected to the cylinder on platform P1 and must be connected to the realignment valve block (B).
-
The pipes of the platform P2 cylinder are connected to the realignment valve block (B) integral with the platform itself.
-
All unconnected fittings/pipes are plugged.
-
Oil tank empty.
All unconnected fittings are plugged.
Proceed as follows to complete the connection (fig.1):
-
Remove the package, position the platforms in the desired place (see lay-out).
N.B.: Insert the pipes before connecting them.
N.B.: Insert all the pipes into the ducts before connecting them.
-
Remove the packaging and position the control unit.
-
Connect the pipes from platform P1 (4-5) to the valve block using the appropriate fittings.
-
Connect the pipes of platform P2 (2-3) to the control unit (1).
-
Fill the tank (6) with ESSO NUTO H32 oil or equivalent (Qt.).
-
Replace the plug-dip rod in the hydraulic control unit (7). Check that the oil level is approx. 10 mm from the cap.
5
4
4
99
P1
P2
2
B
5
3
0579-M2300-0
3
3
6
Rev.n.0 (09/2025)
INDICE
1
2
7