Herunterladen Inhalt Inhalt Diese Seite drucken

Ignite The Pilot Light And Burner - Salvis Master VisionPRO Betriebsanleitung

Gasherd 5,5/10 kw
Vorschau ausblenden Andere Handbücher für Master VisionPRO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.2

Ignite the pilot light and burner

Gas igniter
Gas control for burner, front
Set the burner flame
. After ignition, release the gas control, lightly press and turn to high heating capacity.
. To set from high to small flame, lightly press the gas control and turn to the small flame sym­
bol.
D Low heating capacity, small flame symbol
D High heating capacity, high flame symbol
DANGER! If there is a smell of gas in the room where installed, do not ignite the gas
flame!
Risk of explosion!
. Shut off the gas tap on site!
. Do not switch on or off electrical appliances!
. Open windows and doors! Thoroughly ventilate the room where installed with a
draught!
. After sufficient ventilation, determine the location of escaping gas!
. Inform the standby service of the gas supplier!
Pilot light - under the pilot
burner cover
D When the appliance has not been used for a
longer period of time: e. g. the main shut-off
device was closed, it may take slightly
longer before the pilot light ignites (the gas
supply has to fill up with gas again).
. Press in and hold the gas control, turn to
ignition symbol
. Using the gas igniter, ignite the pilot light.
. After igniting the pilot light, keep the gas
control pressed for approx. 5 ‐ 10 seconds,
− so that the thermocouple can sufficiently
heat up and
− the gas supply is not automatically shut
off again (automatic safety pilot).