Herunterladen Inhalt Inhalt Diese Seite drucken

FLEISCHMANN multiMAUS 686701 Handbuch Seite 53

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.5.
"RESET"
The multiMAUS is a particularly user-friendly digital controller and can be reset to the factory set-
tings, not just completely but also partially.
3.5.1. "CANCEL" can be regarded as the emergency exit from this menu item.
GB
3.5.2. When the "SETTINGS" are reset, all entries in the "Settings" menu are reset to factory set-
tings. The locomotive library remains intact. If calibration has been performed (see 3.5.6.), it
will have to be repeated after the reset.
3.5.3. Select this sub-item if you wish to delete the "LIBRARY".
3.5.4. Select "SPEED STEPS" to reset the selection made in menu item 3.4 to the factory setting.
3.5.5. You can use "FACTORY RESET" to reset your multiMAUS completely to the original status. Any
entries made are deleted.
3.5.6. You will not normally have to "CALIBRATE" the multiMAUS as this is performed on delivery.
However, in the event of extreme temperature variations, the controller may need to be re-
adjusted, e.g. if a locomotive travels in the zero position. To do so, proceed as follows:
– The fi rst screen you see is the "START?" screen. To confi rm, press the "Light / OK" key. "LEFT"
appears on the display screen.
– Turn the controller to the left as far as it will go. To confi rm, press the "Light / OK" key.
"MIDDLE" appears on the display screen.
– Turn the controller to the middle (zero position) and confi rm by pressing the "Light / OK" key.
"RIGHT" appears on the display screen.
– Turn the controller to the right as far as it will go. Once you have confi rmed by pressing the
"Light / OK" key, you return to the start level "RESET".
3.6.
"STOP-MODE"
In the event of an emergency, press the "STOP" key during drive mode to trigger an immediate emer-
gency stop. You determine the exact effect of the emergency stop in menu item "STOP MODE".
3.6.1. "DISABLE VOLTAGE": The entire system is disconnected from the voltage supply;
3.6.2. "EMERGENCY STOP": All locomotives stop immediately but the voltage supply remains in
place.
You can still trigger a "selective emergency stop" which only affects the selected locomotive in spite
of this setting. See page 40.
Factory setting: DISABLE VOLTAGE
– To confi rm, press the "Light / OK" key. You return to the start level "STOP MODE".
3.7.
"INFOS"
A menu item which provides you with information on the software version ("SOFTWARE"), the type
of X-Bus ("X-BUS") and the current master ("COMMAND STATION") in a digital system.
You call up the desired information using one of the "arrow keys". You return to the start level by
pressing the "Light / OK" key.
52
3. T
"S
" M
HE
ETTINGS
ENU

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis