Herunterladen Diese Seite drucken

Fronius RI FB/i Yaskawa WeldCom 2.0 Bedienungsanleitung Seite 24

Werbung

HEX
Adresse
Signal
F007
Control Flag Group 8
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8-15
F008
Working mode
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5-13
Bit 14
Bit 15
F009
Job number
F00A
Program number (xml-file)
F00B
Feeder command value
F00C
Arc length correction
F00D
Puls/Dynamik correction
F00E
Wire retract
F00F
Welding speed
F010
Penetration stabilizer
F011
Arc length stabilizer
F012
Reserved
F013
Reserved
F014
Reserved
F015
Reserved
F016
Reserved
F017
Reserved
24
ExtInput1 => OPT_Output 1
ExtInput2 => OPT_Output 2
ExtInput3 => OPT_Output 3
ExtInput4 => OPT_Output 4
ExtInput5 => OPT_Output 5
ExtInput6 => OPT_Output 6
ExtInput7 => OPT_Output 7
ExtInput8 => OPT_Output 8
Reserved
Working Mode Bit 0
Working Mode Bit 1
Working Mode Bit 2
Working Mode Bit 3
Working Mode Bit 4
Reserved
Command value selection
Reserved
Typ
Einheit / Bereich
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Wertebe-
Siehe
reich Working
mode
auf Seite
26
Boolean
Siehe
Wertebe-
reich Command
value selection
auf Seite
UINT16
0 bis 1000
UINT16
0 bis 65535
SINT16
-327,68 bis
327,67
m/min
SINT16
-10 bis +10
SINT16
-10 bis +10
SINT16
0 bis +10
UINT16
0 bis 65535
(0 bis 6553,5
m/min)
SINT16
0 bis +10
UINT16
0 bis +10
Faktor
26
100
10
10
10
10
10
10

Werbung

loading

Diese Anleitung auch für:

Ri mod/i cc modbus tcp-2p