Herunterladen Diese Seite drucken

Fronius RI FB/i Yaskawa WeldCom 2.0 Bedienungsanleitung Seite 36

Werbung

Ausgangssignale
von der Stromquelle zum Roboter
gültig ab Firmware V1.9.0
HEX
Adresse
Signal
F100
Status Flag Group 1
Bit 0 to 15
F101
Status Flag Group 2
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10 to
11
Bit 12
Bit 13 to
15
F102
Status Flag Group 3
Bit 0 to 13
Bit 14
Bit 15
F103
Status Flag Group 4
Bit 0 to 15
F104
Status Flag Group 5
Bit 0 to 15
F105
Status Flag Group 6
Bit 0 to 15
F106
Status Flag Group 7
Bit 0 to 15
F107
Status Flag Group 8
Bit 0 to 15
F108
Main error number
F109
Reserved
F10A
Welding voltage actual value
36
Reserved
Communication ready
Power source ready
Arc stable
Process active
Main current signal
Torch collision protection
Wire stick control
Wire available
Short circuit timeout
Power out of Range
-
Limit signal High
-
Reserved
Process image Bit 0
Process image Bit 1
Reserved
Reserved
Reserved
Reserved
Reserved
Typ
Bereich / Einheit
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Word
Word
0 bis 65535
(0 bis 100 V)
Faktor

Werbung

loading

Diese Anleitung auch für:

Ri mod/i cc modbus tcp-2p