The device supports five different output control modes, each of them
controllable via phone call or through the mobile application. Choose the control
mode appropriate for your gate automation.
Control mode 1:
- For one or two gates, or one gate with two opening options (partial/ total
opening).
- Both outputs are in an idle state by default and are activated when controlled.
- OUT1 is controlled by calls with caller identification.
- OUT2 is controlled by calls from private (hidden) numbers.
- You can control both outputs separately with the mobile app.
- Gate position limit switches can be connected to inputs IN3 (for gate No. 1)
and IN4 (for gate No. 2).
- A control call/command only opens the gate. Closing must be done
automatically by the gate automation control board.
Control mode 2:
- For one or two gates, or one gate with two opening options (partial/ total
opening).
- Both outputs are in an idle state by default and are activated when controlled.
- Both outputs are controlled by calls with caller identification as configured
(OUT1 only, OUT2 only, or both at the same time).
- You can control both outputs separately with the mobile app.
- Output control permission can be configured separately for each user and
each output.
- Gate position limit switches can be connected to inputs IN3 (for gate No. 1)
and IN4 (for gate No. 2).
- A control call/command only opens the gate. Closing must be done
automatically by the gate automation control board.
Control mode 3:
- For single-gate automations that require triggers for opening and closing on
the same input.
- Opening and then closing by a single call/control command.
- Output OUT1 is in an idle state, while OUT2 is activated by default.
- Output OUT1 is used to control the gate, while OUT2 is used to interrupt the
photocell sensor circuit, thereby providing an option to hold the gate locked in
open state for the configured period.
- Holding the gate locked in an open state permanently on a second call/control
command.
- The gate position limit switch can be connected to input IN3.