GB
MT
Control LEDs on the charger (23):
green
red
lights up —
—
lights up Battery is char-
—
flashes
flashes
flashes
Operation
Working instructions
•
WARNING! Risk of injury! If pos-
sible, use clamps to hold the work-
piece in place. Never hold a small
workpiece in one hand and the
device in the other while using the
device.
•
DANGER! Risk of injury! Ensure
that you have sufficient space in
which to work, and that you do not
endanger other people.
• Adjust the guard cover such that
any sparks or detached parts
cannot hit either the user or any
bystanders.
The guard cover must also be po-
sitioned such that the sparks can-
not ignite combustible parts, in-
cluding those in the surroundings.
• The power tool must not be used
with a cutting stand.
• Only switch on the device when
the attachment tool is not touching
the workpiece.
• Excessive pressure reduces the
performance of the power tool and
leads to faster wear of the attach-
ment tool.
46
Meaning
• Battery is fully
charged
• stand-by (No
battery inser-
ted)
ging
Battery is over-
heated
Battery is defect-
ive
• Always work in the counter-direc-
tion. This ensures that the device is
not pushed out of the cut through
lack of control.
The direction of rotation arrow (7)
symbolises the running direction of
the attachment tool.
• After a heavy load, let the device
idle for a few minutes to cool down
the attachment tool.
• Do not touch the attachment tool
until it has cooled down.
Trial run
Always carry out a trial run without
a load before carrying out your first
procedure as well as after every
tool change. Switch the tool off im-
mediately if the tool is not rotat-
ing smoothly, if considerable vibra-
tion occurs, or if you hear abnormal
noises.
Abrasive cutting
Requirements
• Cutting disc
NOTICE! Property damage. Never
use a roughing disc for cutting!
• diameter ≤ 125 mm
• Thickness ≤ 1.2 mm
• Cutting disk types: diamond
studded, bonded reinforced,
segmented
• Attachment (17) mounted on guard
cover (5)
Notes
• In general, work with a low feed
rate. Exert only moderate pressure
on the work-piece.
Information on building statics
Slits in structural walls are subject
to the country-specific regulations.
These regulations must be observed
without fail.
Before beginning work you should
ask the structural engineer, architect